8/32 3DRE(E)(A); Z3DRE(E)(A) | Proportional pressure reducing valve
BoschRexrothAG, RE29283, edition: 2023-01
Technical data
(For applications outside these values, please consult us!)
Static/dynamic
Type (Z)3DRE (Z)3DREE (Z)3DREA
1600mA 800mA
Hysteresis
5)
% <6 <8 <6 <2
Range of inversion
5)
% <0.5 <0.5 <0.5 < 0.25
Response sensitivity
5)
% <0.5 <0.5 <0.5 < 0.25
Manufacturing tolerance
5)
% ±6 ±6 ±2 ±1
Temperature drift ▶ Electronics %/10K – – <0.3 <0.3
▶ Pressure sensor
– Pressure rating "50" %/10K – – – <0.4
– Pressure rating "100" %/10K – – – <0.2
– Pressure rating "200" %/10K – – – <0.1
– Pressure rating "315" %/10K – – – <0.1
Repetition accuracy
5)
% ±1 ±1 ±1 ±0.5
Linearity
5)
% ±2 ±2 ±2 ±1
Step response T
u
+T
g
6)
▶ 10% → 90% ms 150 250 85
7)
85
7)
▶ 90% → 10% ms 150 250 85
7)
85
7)
Hydraulic fluid Classification Suitable sealing
materials
Standards Datasheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN 51524 90220
Bio-degradable
▶ Insoluble in water HETG FKM
ISO15380
90221HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Flame-resistant ▶ Water-free HFDU (glycol base) FKM
ISO 12922 90222HFDU (ester base) FKM
HFDR FKM
▶ Containing water HFC (Fuchs: Hydrotherm 46M,
Fuchs Renosafe 500;
Petrofer: Ultra Safe 620;
Houghton: Safe 620;
Union: Carbide HP5046)
NBR
ISO 12922 90223
Important information on hydraulic uids:
▶ For further information and data on the use of other
hydraulic fluids, please refer to the datasheets above or
contact us.
▶ There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.).
▶ The ignition temperature of the hydraulic fluid used must be
50K higher than the maximum surface temperature.
▶ Bio-degradable and flame-resistant–containing water:
If components with galvanic zinc coating (e.g.,version"J3" or "J5")
or parts containing zinc are used, small amounts of dissolved
zinc may get into the hydraulic system and cause accelerated
aging of the hydraulic fluid. Zinc soap may form as achemical
reaction product, which may clog filters, nozzles and
solenoid valves–particularly in connection with local heat input.
▶ Flame-resistant–containing water:
– Due to the increased cavitation tendency with the use of
HFChydraulic fluids, the life cycle of the component
may be reduced by up to 30% as compared to the use
with mineral oil HLP.
– Dependent on the hydraulic fluid used, the maximum
environment and hydraulic fluid temperature must not
exceed 50°C. In order to reduce the heat input into the
component, the command value profile is to be adjusted
for proportional and high-response valves.
5)
Of the maximum set pressure
6)
Line volume <20cm
3
, q
V
=0l/min
7)
Adjustment possible up to 70ms